{"product_id":"general-equipment-company-velocimax™-series-ventilation-blower-ep8hl","title":"General Equipment Company VELOCIMAX™ SERIES VENTILATION BLOWER EP8HL","description":"\u003cp\u003e\u003cstrong\u003eFeatures\/Benefits:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCSA certified, multi-point, spark-proof construction to ensure your safety\u003c\/li\u003e\n\u003cli\u003eCorrosion resistant, aluminum motor housing, housing screens \u0026amp; base plus, blower housing\u003c\/li\u003e\n\u003cli\u003eCorrosion resistant, aluminum screws \u0026amp; duct attachment knobs\u003c\/li\u003e\n\u003cli\u003ePVC coated carry handle plus, galvanized coated intake \u0026amp; exhaust screens\u003c\/li\u003e\n\u003cli\u003eIntegral, self-contained ON\/OFF switch with no external wiring\u003c\/li\u003e\n\u003cli\u003eExplosion-proof, totally enclosed, non-vented (TENV) electric motor\u003c\/li\u003e\n\u003cli\u003eHard use cable with spark \u0026amp; ignition-proof plug\u003c\/li\u003e\n\u003cli\u003eSecondary static dispersal system with dual ground path through power cable \u0026amp; duct clamps\u003c\/li\u003e\n\u003cli\u003eOptional statically conductive ducting and aluminum storage canister\u003c\/li\u003e\n\u003cli\u003eIndependent lab certified air flow rates for increased worker safety, productivity plus, meeting stringent Federal \u0026amp; State OSHA requirements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"fusion-fullwidth fullwidth-box fusion-builder-row-2 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" id=\"Specifications\"\u003e\n\u003cdiv class=\"fusion-builder-row fusion-row\"\u003e\n\u003cdiv class=\"fusion-layout-column fusion_builder_column fusion-builder-column-1 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\"\u003e\n\u003cdiv class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"\u003e\n\u003cdiv class=\"fusion-text fusion-text-1\"\u003e\n\u003ch3 data-fontsize=\"24\" data-lineheight=\"28.8px\" class=\"fusion-responsive-typography-calculated\"\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eOperating Environment\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating Environment\u003c\/th\u003e\n\u003ctd\u003eHazardous\/non-hazardous type locations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eVentilation Applications\u003c\/th\u003e\n\u003ctd\u003eNational Electric Code Class I Group D, Class II Group G and Class III hazardous plus, non-hazardous location atmospheres for such things as general fresh air circulation to spot cooling, exhausting fumes \u0026amp; detecting sewer leaks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003ePower Source\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectric Motor\u003c\/th\u003e\n\u003ctd\u003e.33 HP (.25 Kw) 115 VAC, 60 HZ, single speed, explosion-proof, totally enclosed, non-vented (TENV) electric motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eBlower\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eNominal Diameter\u003c\/th\u003e\n\u003ctd\u003e8.0 inches (203.2 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHousing Construction  \u003c\/th\u003e\n\u003ctd\u003eCast aluminum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eImpeller Construction\u003c\/th\u003e\n\u003ctd\u003eSteel, multi-vane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003ePower Cord\u003c\/th\u003e\n\u003ctd\u003e14-3, SOW x 8.5 ft (2.6 M) L, extra hard use cable \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCord Cap\u003c\/th\u003e\n\u003ctd\u003eAppleton NCP2023 or equivalent rated for hazardous location use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eDucting\u003c\/th\u003e\n\u003ctd\u003eOptional statically conductive 8.0 inch (203.2 mm) diameter x 25.0 ft (7.6 M)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eAgency Certifications\u003c\/th\u003e\n\u003ctd\u003eCSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eGeneral\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Dimensions (L x W x H)\u003c\/th\u003e\n\u003ctd\u003e18.9 x 15.4 x 19.9 inches (480.1 x 391.2 x 505.5 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eProduct Weight\u003c\/th\u003e\n\u003ctd\u003e73.0 lbs (33.1 kg), less ventilation duct \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\"\u003eAir Flow Rates\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eConfiguration\u003c\/th\u003e\n\u003cth scope=\"row\"\u003eACFM 15.0 Ft Duct\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eFree Air (Less Duct)\u003c\/th\u003e\n\u003ctd\u003e1277.4 CFM (36.2 CMM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOne 90° Bend\u003c\/th\u003e\n\u003ctd\u003e738.0 CFM (20.9 CMM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eTwo 90° Bend\u003c\/th\u003e\n\u003ctd\u003e578.8 CFM (16.4 CMM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"fusion-clearfix\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"fusion-fullwidth fullwidth-box fusion-builder-row-3 nonhundred-percent-fullwidth non-hundred-percent-height-scrolling\" id=\"Downloads\"\u003e\n\u003cdiv class=\"fusion-builder-row fusion-row\"\u003e\n\u003cdiv class=\"fusion-layout-column fusion_builder_column fusion-builder-column-2 fusion_builder_column_1_1 1_1 fusion-one-full fusion-column-first fusion-column-last\"\u003e\n\u003cdiv class=\"fusion-column-wrapper fusion-flex-column-wrapper-legacy\"\u003e\n\u003cdiv class=\"fusion-text fusion-text-2\"\u003e\n\u003ch3 data-fontsize=\"24\" data-lineheight=\"28.8px\" class=\"fusion-responsive-typography-calculated\"\u003eDownloads\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable class=\"fvm-file-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eLiterature\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003eVersion\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/generalequip.com\/?file=EP8HL-GEF27101001-lit-ver1.2.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eEP8HL VELOCIMAX™ Series Ventilation Blower\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eGEF27101001\u003c\/td\u003e\n\u003ctd\u003e0.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"fvm-file-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eManuals\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003eVersion\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/generalequip.com\/?file=EP8HL-Hazardous-Electric-Blower-Operator-Manual.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eEP8HL Hazardous Location Blower Operator Manual\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eGOM7069501\u003c\/td\u003e\n\u003ctd\u003e1.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"fvm-file-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParts\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003eVersion\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/generalequip.com\/?file=EP8HL-Hazardous-Location-Blower-Parts.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003eEP8HL Hazardous Location Ventilation Blower Parts\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003ePGOM7069501\u003c\/td\u003e\n\u003ctd\u003e1.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ctable class=\"fvm-file-table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eApplication Information\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003cth\u003eVersion\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/generalequip.com\/?file=Ventilation-Blower-Use-During-Confined-Space-Entry-GEF10791091-ver1.0.pdf\" rel=\"noopener noreferrer\" target=\"_blank\"\u003ePortable Air Ventilation Blower Use During Confined Work Space Entry\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eGEF10791091\u003c\/td\u003e\n\u003ctd\u003e1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"General Equipment Company","offers":[{"title":"Default Title","offer_id":50633169043513,"sku":"EP8HL","price":2515.5,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0754\/2938\/0153\/files\/ep8hl-right-face.png?v=1790967567","url":"https:\/\/summitforgesupply.com\/products\/general-equipment-company-velocimax%e2%84%a2-series-ventilation-blower-ep8hl","provider":"Summit Forge Supply","version":"1.0","type":"link"}