{"product_id":"daikin-12000-btu-class-heat-pump-entra-series-outdoor-unit-r32-refrigerant-rxc12axvju","title":"Daikin 12000 BTU Class Heat Pump Entra Series Outdoor Unit - R32 Refrigerant RXC12AXVJU","description":"\u003cp\u003e\u003cspan\u003eThe new Daikin Entra Series boasts R-32 low-GWP refrigerant. R32 is up to 12% more efficient than R410A, resulting in lower Global Warming Potential (GWP). The lower the GWP, the better for the environment. The Daikin Entra Series offers a streamlined design, quiet operation and an inverter \"variable speed\" compressor. No noisy compressor or large ductwork with a Daikin mini split system - only an easily concealed outdoor unit connected to a wall mounted indoor via a pair of copper piping lines to cool your room or zone. These lines are threaded through a small three-inch opening in the wall or ceiling. The modern, wall-mounted indoor units and compact outdoor units blend in discreetly with any home design and run quietly, too. Whether you're enhancing a single room or adding on an entire wing, the system's space-saving, modular design is ideal for set-apart areas like a garage office or nursery.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eQuick and easy duct-free installation\u003c\/li\u003e\n\u003cli\u003ePrecision temperature control for individual rooms\u003c\/li\u003e\n\u003cli\u003eSpace-saving design\u003c\/li\u003e\n\u003cli\u003eQuiet operation\u003c\/li\u003e\n\u003cli\u003eInverter \"variable speed\" compressor\u003c\/li\u003e\n\u003cli\u003eFully optimized for R410A refrigerant, recognized as the future industry standard\u003c\/li\u003e\n\u003cli\u003eOffers world-renowned Daikin technician support and customer service\u003c\/li\u003e\n\u003cli\u003eWorry Free\u003c\/li\u003e\n\u003cli\u003eAuto Restart after Power Failure\u003c\/li\u003e\n\u003cli\u003eAnticorrosion Treatment of Outdoor Heat Exchanger Fin\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e\u003cstrong\u003eThis unit must be installed by a qualified, licensed HVAC technician.\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch3 class=\"normal-case text-lg font-bold leading-6 text-gray-900 px-4 sm:px-6 mb-0 py-3 bg-gray-200\"\u003ePerformance Data\u003c\/h3\u003e\n\u003cdiv class=\"odd:bg-gray-50 px-4 py-3 sm:grid sm:grid-cols-2 sm:gap-4 sm:px-6 hover:bg-gray-100 cursor-pointer\"\u003eCooling BTUs:12000\u003c\/div\u003e\n\u003cdiv class=\"odd:bg-gray-50 px-4 py-3 sm:grid sm:grid-cols-2 sm:gap-4 sm:px-6 hover:bg-gray-100 cursor-pointer\"\u003eIncludes Heat Pump:Yes\u003c\/div\u003e\n\u003cdiv class=\"odd:bg-gray-50 px-4 py-3 sm:grid sm:grid-cols-2 sm:gap-4 sm:px-6 hover:bg-gray-100 cursor-pointer\"\u003eHeat Pump BTUs:11300\u003c\/div\u003e\n\u003cdiv class=\"odd:bg-gray-50 px-4 py-3 sm:grid sm:grid-cols-2 sm:gap-4 sm:px-6 hover:bg-gray-100 cursor-pointer\"\u003eOutdoor Unit Noise Level (dBA):48\u003c\/div\u003e\n\u003ch3 class=\"normal-case text-lg font-bold leading-6 text-gray-900 px-4 sm:px-6 mb-0 py-3 bg-gray-200\"\u003eFeatures\u003c\/h3\u003e\n\u003cdiv class=\"odd:bg-gray-50 px-4 py-3 sm:grid sm:grid-cols-2 sm:gap-4 sm:px-6 hover:bg-gray-100 cursor-pointer\"\u003eInverter Technology:Yes\u003c\/div\u003e\n\u003ch3 class=\"normal-case text-lg font-bold leading-6 text-gray-900 px-4 sm:px-6 mb-0 py-3 bg-gray-200\"\u003ePiping \/ Line Set Requirements\u003c\/h3\u003e\n\u003cdiv class=\"odd:bg-gray-50 px-4 py-3 sm:grid sm:grid-cols-2 sm:gap-4 sm:px-6 hover:bg-gray-100 cursor-pointer\"\u003eLine Set Liquid Line:1\/4\"\u003c\/div\u003e\n\u003cdiv class=\"odd:bg-gray-50 px-4 py-3 sm:grid sm:grid-cols-2 sm:gap-4 sm:px-6 hover:bg-gray-100 cursor-pointer\"\u003eLine Set Suction Line:3\/8\"\u003c\/div\u003e\n\u003cdiv class=\"odd:bg-gray-50 px-4 py-3 sm:grid sm:grid-cols-2 sm:gap-4 sm:px-6 hover:bg-gray-100 cursor-pointer\"\u003eMaximum Pipe Length (ft.):65.625\u003c\/div\u003e\n\u003cdiv class=\"odd:bg-gray-50 px-4 py-3 sm:grid sm:grid-cols-2 sm:gap-4 sm:px-6 hover:bg-gray-100 cursor-pointer\"\u003eMax. Height Difference (Indoor \/ Outdoor) (ft.):32.813\u003c\/div\u003e\n\u003ch3 class=\"normal-case text-lg font-bold leading-6 text-gray-900 px-4 sm:px-6 mb-0 py-3 bg-gray-200\"\u003eOperating Range\u003c\/h3\u003e\n\u003cdiv class=\"odd:bg-gray-50 px-4 py-3 sm:grid sm:grid-cols-2 sm:gap-4 sm:px-6 hover:bg-gray-100 cursor-pointer\"\u003eAmbient Temperature Range - Cooling:50°F - 115°F\u003c\/div\u003e\n\u003cdiv class=\"odd:bg-gray-50 px-4 py-3 sm:grid sm:grid-cols-2 sm:gap-4 sm:px-6 hover:bg-gray-100 cursor-pointer\"\u003eAmbient Temperature Range - Heating:5°F - 65°F\u003c\/div\u003e\n\u003cdiv class=\"odd:bg-gray-50 px-4 py-3 sm:grid sm:grid-cols-2 sm:gap-4 sm:px-6 hover:bg-gray-100 cursor-pointer\"\u003eMin. Outdoor Temp for Heat °F:5\u003c\/div\u003e\n\u003ch3 class=\"normal-case text-lg font-bold leading-6 text-gray-900 px-4 sm:px-6 mb-0 py-3 bg-gray-200\"\u003eWeights and Dimensions\u003c\/h3\u003e\n\u003cdiv class=\"odd:bg-gray-50 px-4 py-3 sm:grid sm:grid-cols-2 sm:gap-4 sm:px-6 hover:bg-gray-100 cursor-pointer\"\u003eWidth (in.):26.5\u003c\/div\u003e\n\u003cdiv class=\"odd:bg-gray-50 px-4 py-3 sm:grid sm:grid-cols-2 sm:gap-4 sm:px-6 hover:bg-gray-100 cursor-pointer\"\u003eDepth (in.):11.188\u003c\/div\u003e\n\u003cdiv class=\"odd:bg-gray-50 px-4 py-3 sm:grid sm:grid-cols-2 sm:gap-4 sm:px-6 hover:bg-gray-100 cursor-pointer\"\u003eHeight (in.):21.688\u003c\/div\u003e\n\u003cdiv class=\"odd:bg-gray-50 px-4 py-3 sm:grid sm:grid-cols-2 sm:gap-4 sm:px-6 hover:bg-gray-100 cursor-pointer\"\u003eWeight (lbs.):60\u003c\/div\u003e\n\u003ch3 class=\"normal-case text-lg font-bold leading-6 text-gray-900 px-4 sm:px-6 mb-0 py-3 bg-gray-200\"\u003eElectrical Requirements\u003c\/h3\u003e\n\u003cdiv class=\"odd:bg-gray-50 px-4 py-3 sm:grid sm:grid-cols-2 sm:gap-4 sm:px-6 hover:bg-gray-100 cursor-pointer\"\u003eVoltage:208-230V\u003c\/div\u003e\n\u003cdiv class=\"odd:bg-gray-50 px-4 py-3 sm:grid sm:grid-cols-2 sm:gap-4 sm:px-6 hover:bg-gray-100 cursor-pointer\"\u003eAmps:.61\u003c\/div\u003e\n\u003cdiv class=\"odd:bg-gray-50 px-4 py-3 sm:grid sm:grid-cols-2 sm:gap-4 sm:px-6 hover:bg-gray-100 cursor-pointer\"\u003eCircuit Breaker Size (Amps):15\u003c\/div\u003e\n\u003cdiv class=\"odd:bg-gray-50 px-4 py-3 sm:grid sm:grid-cols-2 sm:gap-4 sm:px-6 hover:bg-gray-100 cursor-pointer\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"odd:bg-gray-50 px-4 py-3 sm:grid sm:grid-cols-2 sm:gap-4 sm:px-6 hover:bg-gray-100 cursor-pointer\"\u003e\n\u003cul class=\"manuals\"\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/manuals.totalhomesupply.com\/wp-content\/uploads\/manuals\/R32-Entra-Oterra-Operation-Manual.pdf\" target=\"_blank\"\u003eEntra Oterra R32 Operation Instructions\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/manuals.totalhomesupply.com\/wp-content\/uploads\/manuals\/R32-Entra-Engineering-Manual.pdf\" target=\"_blank\"\u003e\u003cspan class=\"pdficon\"\u003e\u003c\/span\u003eEntra R32 Engineering Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/manuals.totalhomesupply.com\/wp-content\/uploads\/manuals\/R32-Entra-Service-Manual.pdf\" target=\"_blank\"\u003e\u003cspan class=\"pdficon\"\u003e\u003c\/span\u003eEntra R32 Service Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Daikin","offers":[{"title":"Default Title","offer_id":51196608643129,"sku":"RXC12AXVJU","price":847.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0754\/2938\/0153\/files\/outdoor__89301.webp?v=1794716272","url":"https:\/\/summitforgesupply.com\/products\/daikin-12000-btu-class-heat-pump-entra-series-outdoor-unit-r32-refrigerant-rxc12axvju","provider":"Summit Forge Supply","version":"1.0","type":"link"}