{"product_id":"air-care-triox-20-commercial-ozone-generator-fg0289","title":"Air-Care TriOx-20 Commercial Ozone Generator FG0289","description":"\u003cdiv class=\"elementor-element elementor-element-8f3788d e-con-full e-flex e-con e-child\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-921d9ee elementor-widget elementor-widget-text-editor\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e[!CAUTION!] UNOCCUPIED SPACES ONLY\u003c\/strong\u003e\u003c\/span\u003e: Ozone in high concentrations is hazardous to humans and animals. Never operate the TriOx-20 in a room occupied by people, pets, or live plants.\u003c\/p\u003e\n\u003cp\u003eTreatment Area: Ensure the area being treated is completely sealed off from occupied rooms. Place warning door hangers on all entrances.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePost-Treatment Ventilation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAfter the timer expires, wait at least 30–60 minutes for the ozone to dissipate back into oxygen before re-entering the area. If possible, open windows and doors to accelerate ventilation. You can also use our ozone meter (optional) to test the air in the room(s)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRespiratory Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIf you must enter a room while the machine is operating, wear a properly rated O3-respirator mask.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlammability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDo not use the TriOx-20 in environments with high concentrations of flammable gases, vapors, or explosives.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Safety:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsure the machine is plugged into a grounded (three-prong) outlet. Do not operate with a damaged cord or in wet\/high-moisture conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWarning Label:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOn the top of the TriOx-20 there is a warning label that should be read before operating the device.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-3e693d4 e-con-full e-flex e-con e-child\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-7e3cb25 elementor-widget elementor-widget-image\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\u003cimg decoding=\"async\" width=\"1332\" height=\"1332\" src=\"https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/01\/01-DOORHANGER-3.5X8.5.png?fit=1332%2C1332\u0026amp;ssl=1\" class=\"attachment-full size-full wp-image-7390\" alt=\"\" srcset=\"https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/01\/01-DOORHANGER-3.5X8.5.png?w=1332\u0026amp;ssl=1 1332w, https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/01\/01-DOORHANGER-3.5X8.5.png?resize=300%2C300\u0026amp;ssl=1 300w, https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/01\/01-DOORHANGER-3.5X8.5.png?resize=1024%2C1024\u0026amp;ssl=1 1024w, https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/01\/01-DOORHANGER-3.5X8.5.png?resize=150%2C150\u0026amp;ssl=1 150w, https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/01\/01-DOORHANGER-3.5X8.5.png?resize=768%2C768\u0026amp;ssl=1 768w\" sizes=\"(max-width: 800px) 100vw, 800px\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-5cfa4e8 elementor-widget elementor-widget-video\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\n\u003cdiv class=\"elementor-wrapper elementor-open-inline\"\u003e\u003ciframe class=\"elementor-video\" title=\"TriOx-20 Ozone Generator Safety Procedures: The Complete Guide\" width=\"640\" height=\"360\" src=\"https:\/\/www.youtube.com\/embed\/UIKAq6mYOAs?controls=1\u0026amp;rel=0\u0026amp;playsinline=0\u0026amp;modestbranding=0\u0026amp;autoplay=0\u0026amp;enablejsapi=1\u0026amp;origin=https%3A%2F%2Fguides.air-care.com\u0026amp;widgetid=1\u0026amp;forigin=https%3A%2F%2Fguides.air-care.com%2Ftriox-20-commercial-ozone-generator-user-manual%2F\u0026amp;aoriginsup=1\u0026amp;gporigin=https%3A%2F%2Fwww.google.com%2F\u0026amp;vf=1\" id=\"widget2\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003cdiv class=\"elementor-wrapper elementor-open-inline\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-cd93d50 e-con-full e-flex e-con e-parent\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-22c613f e-con-full e-flex e-con e-child\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-fd28fe5 elementor-widget elementor-widget-text-editor\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\n\u003ch2\u003e\u003cspan\u003eInstalling the UV-C Light\u003c\/span\u003e\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-5d40466 e-grid e-con-boxed e-con e-parent\"\u003e\n\u003cdiv class=\"e-con-inner\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-ac0605a elementor-widget elementor-widget-image\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\u003cimg decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/06\/TriOx-20-UVC-Lamp-2.png?fit=1024%2C1024\u0026amp;ssl=1\" class=\"attachment-full size-full wp-image-7459\" alt=\"\" srcset=\"https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/06\/TriOx-20-UVC-Lamp-2.png?w=1024\u0026amp;ssl=1 1024w, https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/06\/TriOx-20-UVC-Lamp-2.png?resize=300%2C300\u0026amp;ssl=1 300w, https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/06\/TriOx-20-UVC-Lamp-2.png?resize=150%2C150\u0026amp;ssl=1 150w, https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/06\/TriOx-20-UVC-Lamp-2.png?resize=768%2C768\u0026amp;ssl=1 768w\" sizes=\"(max-width: 800px) 100vw, 800px\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-c27d650 elementor-widget elementor-widget-text-editor\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\n\u003ch2\u003e\u003cstrong\u003e1. About UV-C\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eUV-C light is a type of ultraviolet radiation with wavelengths between 200 and 280 nanometers, often referred to as “germicidal” light because of its ability to deactivate microorganisms. It works by penetrating the thin cell walls of bacteria, viruses, and protozoa, where the high-energy photons disrupt the molecular bonds of the organism’s DNA or RNA. This damage creates thymine dimers that prevent the pathogen from replicating or performing vital cellular functions, effectively rendering it harmless.\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e\u003cstrong\u003eSafety and Dangers\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eWhile highly effective for sterilization, UV-C light is extremely hazardous to humans and animals. Because it is energetic enough to break chemical bonds, even brief exposure can cause:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePhotokeratitis:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOften described as a “sunburn of the eye,” causing severe pain, light sensitivity, and a feeling of sand in the eyes. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eErythema\u003c\/strong\u003e: Intense, painful skin reddening similar to a severe sunburn. Long-term Risks: Prolonged or repeated exposure can lead to cataracts, retinal damage, and an increased risk of skin cancer.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eBecause UV-C is invisible to the human eye, it is critical to use these devices only in shielded environments or unoccupied spaces with automated shut-off sensors to prevent accidental exposure.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-1d81d03 e-grid e-con-boxed e-con e-parent\"\u003e\n\u003cdiv class=\"e-con-inner\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-a0b5a82 elementor-widget elementor-widget-image\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\u003cimg loading=\"lazy\" decoding=\"async\" width=\"444\" height=\"444\" src=\"https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/06\/bulb-attachment-1.png?fit=444%2C444\u0026amp;ssl=1\" class=\"attachment-large size-large wp-image-7465\" alt=\"\" srcset=\"https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/06\/bulb-attachment-1.png?w=444\u0026amp;ssl=1 444w, https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/06\/bulb-attachment-1.png?resize=300%2C300\u0026amp;ssl=1 300w, https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/06\/bulb-attachment-1.png?resize=150%2C150\u0026amp;ssl=1 150w\" sizes=\"(max-width: 444px) 100vw, 444px\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-af75d48 elementor-widget elementor-widget-image\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\u003cimg loading=\"lazy\" decoding=\"async\" width=\"444\" height=\"444\" src=\"https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/06\/bulb-attachment-2-3.png?fit=444%2C444\u0026amp;ssl=1\" class=\"attachment-large size-large wp-image-7466\" alt=\"\" srcset=\"https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/06\/bulb-attachment-2-3.png?w=444\u0026amp;ssl=1 444w, https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/06\/bulb-attachment-2-3.png?resize=300%2C300\u0026amp;ssl=1 300w, https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/06\/bulb-attachment-2-3.png?resize=150%2C150\u0026amp;ssl=1 150w\" sizes=\"(max-width: 444px) 100vw, 444px\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-896b368 elementor-widget elementor-widget-text-editor\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\n\u003cp\u003e\u003cstrong\u003e1.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRemove the two screws that attaches the face plate to the TriOx-20 and carefully remove the face plate.\u003c\/p\u003e\n\u003cp\u003e2. A box with the UV-C lamp will be inside the unit for safety during shipping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e3. ALWAYS HANDLE the lamp with the provided gloves inside to protect the lamp.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRemove the box and then CAREFULLY remove the lamp from the box. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-c227a31 e-grid e-con-boxed e-con e-parent\"\u003e\n\u003cdiv class=\"e-con-inner\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-ae58033 elementor-widget elementor-widget-image\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\u003cimg loading=\"lazy\" decoding=\"async\" width=\"446\" height=\"446\" src=\"https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/06\/bulb-attachment-4.png?fit=446%2C446\u0026amp;ssl=1\" class=\"attachment-large size-large wp-image-7467\" alt=\"\" srcset=\"https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/06\/bulb-attachment-4.png?w=446\u0026amp;ssl=1 446w, https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/06\/bulb-attachment-4.png?resize=300%2C300\u0026amp;ssl=1 300w, https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/06\/bulb-attachment-4.png?resize=150%2C150\u0026amp;ssl=1 150w\" sizes=\"(max-width: 446px) 100vw, 446px\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-7c3f992 elementor-widget elementor-widget-image\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\u003cimg loading=\"lazy\" decoding=\"async\" width=\"424\" height=\"424\" src=\"https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/06\/bulb-attachment-5.png?fit=424%2C424\u0026amp;ssl=1\" class=\"attachment-large size-large wp-image-7464\" alt=\"\" srcset=\"https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/06\/bulb-attachment-5.png?w=425\u0026amp;ssl=1 425w, https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/06\/bulb-attachment-5.png?resize=300%2C300\u0026amp;ssl=1 300w, https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/06\/bulb-attachment-5.png?resize=150%2C150\u0026amp;ssl=1 150w\" sizes=\"(max-width: 424px) 100vw, 424px\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-8e7de8b elementor-widget elementor-widget-text-editor\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\n\u003cp\u003e\u003cstrong\u003e4.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePlace the lamp in the socket inside the TriOx-20.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e5.\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePlace the two original screws, along with the 5 other screws (included), to close and secure the face plate.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e\u003cstrong\u003eNEVER TOUCH A UV-C BULB WITH YOUR BARE HANDS!\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-ef87d6d e-flex e-con-boxed e-con e-parent\"\u003e\n\u003cdiv class=\"e-con-inner\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-c4b3fa8 e-flex e-con-boxed e-con e-child\"\u003e\n\u003cdiv class=\"e-con-inner\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-b774108 elementor-align-center elementor-widget elementor-widget-button\" id=\"page-menu\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\n\u003cdiv class=\"elementor-button-wrapper\"\u003e\u003ca class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/guides.air-care.com\/triox-20-commercial-ozone-generator-user-manual\/#\"\u003e\u003cspan class=\"elementor-button-content-wrapper\"\u003e\u003cspan class=\"elementor-button-text\"\u003eBack to Top\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-35a8d29 e-con-full e-flex e-con e-parent\" id=\"row3\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-6320d14 e-flex e-con-boxed e-con e-child\"\u003e\n\u003cdiv class=\"e-con-inner\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-2b763cf elementor-widget elementor-widget-text-editor\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\n\u003ch2\u003e\u003cspan\u003eTreatment Times\u003c\/span\u003e\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-1d1b484 e-flex e-con-boxed e-con e-parent\"\u003e\n\u003cdiv class=\"e-con-inner\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-a5647c7 e-con-full e-flex e-con e-child\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-a720667 elementor-widget elementor-widget-image\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\u003cimg loading=\"lazy\" decoding=\"async\" width=\"695\" height=\"695\" src=\"https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/01\/TriOx-20-Treatment-Times.png?fit=695%2C695\u0026amp;ssl=1\" class=\"attachment-large size-large wp-image-7286\" alt=\"\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-06da490 e-flex e-con-boxed e-con e-child\"\u003e\n\u003cdiv class=\"e-con-inner\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-228d3c7 elementor-align-center elementor-widget elementor-widget-button\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\n\u003cdiv class=\"elementor-button-wrapper\"\u003e\u003ca class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/guides.air-care.com\/triox-20-commercial-ozone-generator-user-manual\/#\"\u003e\u003cspan class=\"elementor-button-content-wrapper\"\u003e\u003cspan class=\"elementor-button-text\"\u003eBack to Top\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-43cad21 e-con-full e-flex e-con e-parent\" id=\"row4\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-1af1fa6 e-flex e-con-boxed e-con e-child\"\u003e\n\u003cdiv class=\"e-con-inner\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-fb76494 elementor-widget elementor-widget-text-editor\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\n\u003ch2\u003e\u003cspan\u003eOPERATING THE TRIOX-20\u003c\/span\u003e\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-ada5e2e e-flex e-con-boxed e-con e-parent\"\u003e\n\u003cdiv class=\"e-con-inner\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-948205c elementor-widget elementor-widget-text-editor\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\n\u003cp\u003eThe effective concentration of ozone for odor destruction typically ranges from very low levels for minor air freshening to high concentrations for professional “shock” treatments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-f65502a e-con-full e-flex e-con e-parent\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-07f4249 e-con-full e-flex e-con e-child\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-e458b3e elementor-widget__width-initial elementor-widget elementor-widget-text-editor\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\n\u003ch2\u003eEffective Concentrations for Odor Removal\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eMinor Air Purification:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConcentrations between 0.02 and 0.08 ppm are generally sufficient for deodorizing air and removing light odors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntensive “Shock” Treatment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFor stubborn odors like smoke, mold, or decay, a minimum concentration of 5.0 ppm is often required to permanently eliminate resistant odors and bacteria. (SEE NEXT SECTION ON SHOCK TREATMENTS)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommercial\/Industrial Odor Control:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProfessional applications may target concentrations between 1.0 and 2.0 ppm for general disinfection and stronger odor control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eWarning: Concentrations of 5.0 ppm or higher are considered immediately dangerous to life or health. Refer to the OSHA warning label on top of the TriOx-20 unit.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eHigh-concentration ozone treatments must only be performed in unoccupied spaces (no people, pets, or plants) and require thorough ventilation (typically 2 to 24 hours) before re-entry. \u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-eab0b42 e-con-full e-flex e-con e-child\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-ff73952 elementor-widget elementor-widget-text-editor\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\n\u003ch2\u003eKey Effectiveness Factors\u003cbr\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCT Value (Concentration × Time):\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe total effectiveness depends on both the concentration and how long it is maintained. For example, a lower concentration (0.2 ppm) run for a longer period can achieve the same result as a higher concentration (0.4 ppm) run for a shorter time.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOdor Threshold:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eHumans can typically detect the “metallic” or “chlorine-like” smell of ozone at levels as low as 0.01 to 0.03 ppm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety and Regulatory Limits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBecause ozone is a toxic gas, safety standards strictly limit human exposure to levels far below what is needed for intensive odor removal:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOccupied Spaces:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFederal agencies like OSHA and NIOSH recommend an exposure limit of no more than 0.1 ppm for an 8-hour period.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMedical Devices:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe FDA requires ozone output for indoor medical devices to be no more than 0.05 ppm.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-f082caf e-flex e-con-boxed e-con e-parent\"\u003e\n\u003cdiv class=\"e-con-inner\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-ef443d8 e-con-full e-flex e-con e-child\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-222ad02 elementor-align-center elementor-widget elementor-widget-button\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\n\u003cdiv class=\"elementor-button-wrapper\"\u003e\u003ca class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/guides.air-care.com\/triox-20-commercial-ozone-generator-user-manual\/#\"\u003e\u003cspan class=\"elementor-button-content-wrapper\"\u003e\u003cspan class=\"elementor-button-text\"\u003eBack to Top\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-764aafa e-con-full e-flex e-con e-parent\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-6845527 e-con-full e-flex e-con e-child\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-edf5cbe elementor-widget elementor-widget-text-editor\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\n\u003ch2\u003e\u003cspan\u003eOPERATING THE OZONE DETECTOR\u003c\/span\u003e\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-6cf8e2b e-flex e-con-boxed e-con e-parent\"\u003e\n\u003cdiv class=\"e-con-inner\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-645cd97 e-con-full e-flex e-con e-child\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-791534b elementor-widget elementor-widget-image\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\u003cimg loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/01\/Ozone-Detector-Line-Art.png?fit=800%2C800\u0026amp;ssl=1\" class=\"attachment-large size-large wp-image-7376\" alt=\"\" srcset=\"https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/01\/Ozone-Detector-Line-Art.png?w=1024\u0026amp;ssl=1 1024w, https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/01\/Ozone-Detector-Line-Art.png?resize=300%2C300\u0026amp;ssl=1 300w, https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/01\/Ozone-Detector-Line-Art.png?resize=150%2C150\u0026amp;ssl=1 150w, https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/01\/Ozone-Detector-Line-Art.png?resize=768%2C768\u0026amp;ssl=1 768w\" sizes=\"(max-width: 800px) 100vw, 800px\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-9f85546 elementor-widget elementor-widget-text-editor\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\n\u003cp\u003e\u003cstrong\u003eCharging:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eWhen low battery icon is displayed the device needs to be charged. Insert the type-C charging cable into the devic e. Attach the other end to a USB DC charger. Fully charge for at least 2-3 hours before use. Avoid charging with a USB computer port which only outputs 500mA\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-fb60b9e e-con-full e-flex e-con e-child\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-f398306 elementor-widget elementor-widget-text-editor\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\n\u003ch2\u003eHow to Use\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTurn Off\/On: a)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn power-off state, long press Right Button to turn on the device.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eb)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIn power-on state, long press Right Button to turn off the device. If the device will not turn on, plug-in and charge the Detector.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAQI (O3 concentration): \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-b84484e elementor-widget elementor-widget-image\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\u003cimg loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"118\" src=\"https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/01\/AQI-Graphic.png?fit=800%2C118\u0026amp;ssl=1\" class=\"attachment-large size-large wp-image-7372\" alt=\"\" srcset=\"https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/01\/AQI-Graphic.png?w=1105\u0026amp;ssl=1 1105w, https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/01\/AQI-Graphic.png?resize=300%2C44\u0026amp;ssl=1 300w, https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/01\/AQI-Graphic.png?resize=1024%2C151\u0026amp;ssl=1 1024w, https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/2026\/01\/AQI-Graphic.png?resize=768%2C113\u0026amp;ssl=1 768w\" sizes=\"(max-width: 800px) 100vw, 800px\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-5857ebb elementor-widget elementor-widget-text-editor\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\n\u003cp\u003e\u003cstrong\u003eO3 Alarm: a)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eO3 alarm value is 1.00 ppm.\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eb)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSingle-press\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eLeft Button\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto turn on\/off the O3 alarm sound.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSleep Mode:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Default sleep mode is\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOFF\u003c\/strong\u003e) Double click left button.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe buzzer beeps long 1 time:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eActivate Sleep Mode (If there is no operation for 60 seconds, the display screen will turn off to save power consumption, but the device is still working normally. Any click on the left or right button will light up the display screen).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe buzzer beeps 2 times:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExit sleep mode.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Unit: a)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDouble press Right Button to switch the temperature unit between Celsius (C) and Fahrenheit (F)\u003c\/p\u003e\n\u003cdiv class=\"elementor-element elementor-element-7555bcb elementor-widget__width-initial elementor-widget elementor-widget-text-editor\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\n\u003cp\u003eThe TriOx-20 timer is an electronic countdown timer featuring single-button operation for preset times and a separate “Hold” mode for continuous operation. No complex programming is required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTurning ON and Selecting Time (Timer Mode):\u003c\/strong\u003e\u003cbr\u003ePress and release the main push button repeatedly to cycle through the available preset countdown times: 1 hour, 2 hours, 4 hours, and 8 hours, or to select OFF.\u003c\/p\u003e\n\u003cp\u003eThe illuminated LED light next to the selected time setting indicates the current active countdown duration.\u003c\/p\u003e\n\u003cp\u003eThe connected fan, UVC lamp, and ozone generator will turn ON and remain on for the selected time interval, then automatically turn OFF when the time counts down to zero.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContinuous Operation (Hold Mode):\u003c\/strong\u003e\u003cbr\u003eTo turn the unit ON for an extended or continuous period of time, press and hold the main push button for more than 2 seconds.\u003c\/p\u003e\n\u003cp\u003eThe timer will enter “HOLD” mode, and the dedicated “HOLD” LED will turn on to indicate continuous operation. The fan will stay on indefinitely until manually turned off or the mode is exited.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExiting Any Mode and Turning OFF:\u003c\/strong\u003e\u003cbr\u003eTo turn the timer OFF from any mode (Timer or Hold), press and release the main push button.\u003cbr\u003eAll LEDs will turn off, and the TriOx-20 unit will be switched OFF.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-ac7bb37 elementor-widget elementor-widget-image\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\n\u003cimg decoding=\"async\" src=\"https:\/\/i0.wp.com\/guides.air-care.com\/wp-content\/uploads\/elementor\/thumbs\/TriOx-20-Timer-rh9oj8wvmsssi0s0vmp9072ypbqdap7ourfcnq1c9k.png?w=800\u0026amp;ssl=1\" title=\"TriOx-20 Timer\" alt=\"TriOx-20 Timer\" loading=\"lazy\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-57bc02d e-con-full e-flex e-con e-parent\" id=\"row7\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-65b2d4d elementor-widget elementor-widget-text-editor\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\n\u003cp\u003eShock treatment is a high-intensity decontamination process used to permanently eliminate severe odors by flooding an unoccupied space with lethal concentrations of ozone gas. Unlike low-level air purification, shock treatments target the molecular source of odors embedded in surfaces and fabrics.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-dd48c0c e-flex e-con-boxed e-con e-parent\"\u003e\n\u003cdiv class=\"e-con-inner\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-28219f3 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\n\u003ch3\u003e1. Preparation\u003c\/h3\u003e\n\u003cp\u003eBefore the machine is even plugged in, the environment must be “cleared and sealed.” High levels of ozone are toxic and corrosive. Place the warning door hanger on all entrances.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Total Evacuation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRemove all people, pets, and living plants. Ozone kills plant tissues.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Clean the Source: \u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOzone works best on residual odors. Remove the physical source (trash, mold, or spills) first.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Protect Materials:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRemove or cover items made of natural rubber (elastic, gaskets), delicate fabrics (silk, fine wool), and expensive electronics to prevent oxidative damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Seal the Space:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eClose all windows and doors. Use painters’ tape or a damp towel at the base of the door to prevent gas from leaking into occupied areas.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Set the Timer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe TriOx-20 has a manual timer. Ensure it is set so the machine turns off automatically. \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-1463fac elementor-widget__width-initial elementor-widget elementor-widget-text-editor\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\n\u003ch3\u003e2. Saturation\u003c\/h3\u003e\n\u003cp\u003eThis is the phase where the ozone generator is active and the concentration builds up to the “lethal” level required to kill odors.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e• Placement:\u003c\/span\u003e Place the generator in a high location (ozone is heavier than air and will sink) and place a 20” x 20” box fan (sold separately) in front of the unit, to help the gas distribute.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e• Concentration:\u003c\/span\u003e For a “shock” effect, the goal is to reach 5.0 ppm or higher.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e• Duration: *\u003c\/span\u003e (See time estimates on page 2)\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eVehicles:\u003c\/span\u003e 15–45 minutes.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e• Small\/Standard Rooms:\u003c\/span\u003e 1–4 hours.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e• Extreme Cases (Fire\/Flood):\u003c\/span\u003e Up to 24–48 hours. We suggest using a box fan for higher ozone distribution.\u003c\/p\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-fac125b e-flex e-con-boxed e-con e-parent\"\u003e\n\u003cdiv class=\"e-con-inner\"\u003e\n\u003cdiv class=\"elementor-element elementor-element-4305d54 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\n\u003ch3\u003e3. Oxidation\u003c\/h3\u003e\n\u003cp\u003eDuring this phase, the O3 molecules go to work at a molecular level.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Chemical Action:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe unstable third oxygen atom breaks away and attaches to odor-causing molecules, bacteria, and mold spores.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Molecular Destruction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThis process permanently alters the chemical structure of the odor, essentially “burning” it at a microscopic level rather than just masking it with a scent.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Penetration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBecause it is a gas, the ozone saturates porous materials like carpets, drywall, and upholstery to reach odors embedded deep within surfaces. \u003c\/p\u003e\n\u003ch3\u003e \u003c\/h3\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"elementor-element elementor-element-320b351 elementor-widget__width-initial elementor-widget elementor-widget-text-editor\"\u003e\n\u003cdiv class=\"elementor-widget-container\"\u003e\n\u003ch3\u003e4. Reversion \u0026amp; Ventilation\u003c\/h3\u003e\n\u003cp\u003eOnce the machine shuts off, the ozone must safely turn back into breathable oxygen before anyone can enter.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e• The “Wait Period”:\u003c\/span\u003e Ozone has a half-life of roughly 20 minutes. You must keep the room sealed for at least 1 to 2 hours after the machine stops to allow the majority of the O2 to revert to O2.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e• Initial Entry:\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eQuickly enter the room and use the ozone tester to measure the levels in the room. Open windows and turn on exhaust fans, then leave immediately.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e• Aggressive Ventilation:\u003c\/span\u003e Let the room air out for an additional 1 to 4 hours.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e• Final Check:\u003c\/span\u003e Do not resume normal occupancy until you test for .03 ppm levels using an ozone detector (optional).                                                 \u003c\/p\u003e\n\u003ctable id=\"tablepress-47\" class=\"tablepress tablepress-id-47 dataTable no-footer\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"row-1 odd\"\u003e\n\u003cth class=\"column-1 sorting\" rowspan=\"1\" colspan=\"1\" tabindex=\"0\"\u003eItem\u003c\/th\u003e\n\u003cth class=\"column-2 sorting\" rowspan=\"1\" colspan=\"1\" tabindex=\"0\"\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody class=\"row-hover\"\u003e\n\u003ctr class=\"row-2 even\"\u003e\n\u003ctd class=\"column-1\"\u003eOzone Output\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eDual 10,000 mg\/hr generators (20,000 mg\/hr max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-3 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eAirflow\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e250 CFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-4 even\"\u003e\n\u003ctd class=\"column-1\"\u003eHousing Material\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eCross-Linked Polyethylene (XLP\/PEX) – Ozone Resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-5 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eGermicidal Irradiation\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eUVC Bulb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-6 even\"\u003e\n\u003ctd class=\"column-1\"\u003eControls\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eIndividual generator switches, master power switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-7 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eSafety Indicator\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003eIntegrated warning light\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-8 even\"\u003e\n\u003ctd class=\"column-1\"\u003ePower Requirements\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e120v, 289w\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-9 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eAMPS\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e4.41 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-10 even\"\u003e\n\u003ctd class=\"column-1\"\u003eDimensions\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e14.4” x 19.5” x 14”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"row-11 odd\"\u003e\n\u003ctd class=\"column-1\"\u003eWeight\u003c\/td\u003e\n\u003ctd class=\"column-2\"\u003e13 lbs.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e         \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Air-Care","offers":[{"title":"Default Title","offer_id":46407609614393,"sku":"FG0289","price":895.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0754\/2938\/0153\/files\/Screenshot2026-08-29235634.png?v=1788062205","url":"https:\/\/summitforgesupply.com\/products\/air-care-triox-20-commercial-ozone-generator-fg0289","provider":"Summit Forge Supply","version":"1.0","type":"link"}