{"product_id":"aciq-4-ton-16-seer2-high-efficiency-heat-pump-condenser-r454b-inverter-aciq-48-ehpd","title":"ACIQ 4 Ton 16 SEER2 High Efficiency Heat Pump Condenser - R454B Inverter ACIQ-48-EHPD","description":"\u003cp\u003e\u003cb\u003eInverter\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e- The ACiQ-48-EHPD 4 ton central inverter heat pump utilizes inverter technology to convert AC power to DC, allowing the compressor to adjust its speed. This enables the condenser to modify its BTU output based on the current demand, providing efficient and adaptable performance throughout varying weather conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eLearning Condenser\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e- Equipped with advanced sensors, this condenser monitors indoor and outdoor air temperature, duct pressure, refrigerant temperature, and overall performance. During the initial startup, it enters a learning mode, optimizing future operations for maximum efficiency by collecting and storing data.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAdaptive Sizing\u003c\/b\u003e\u003cspan\u003e \u003c\/span\u003e- With its self-adjusting inverter design, the ACiQ-48-EHPD can be sized based on your heating needs. Standard heat pumps may cause discomfort during summer when sized for heat, but this unit automatically adjusts to function like a smaller unit, ensuring ideal cooling performance without excess humidity.\u003c\/p\u003e\n\u003ch3\u003eQUICK FACTS\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVariable output based on demand: 12,000-48,000 BTU for cooling, 12,000-48,000 BTU for heating\u003c\/li\u003e\n\u003cli\u003eR454B refrigerant\u003c\/li\u003e\n\u003cli\u003eInverter heat pump system for ducted applications\u003c\/li\u003e\n\u003cli\u003eEfficient cooling from -13°F to 122°F outdoor temperatures\u003c\/li\u003e\n\u003cli\u003eReliable heating from -13°F to 75°F outdoor temperatures\u003c\/li\u003e\n\u003cli\u003eDurable gold fin condenser coil coating for longevity\u003c\/li\u003e\n\u003cli\u003eQuiet operation, even under high workloads\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e4 Ton, 16 SEER2\u003c\/h3\u003e\n\u003cp\u003eBoasting an efficiency rating of 16 SEER2, the ACiQ-48-EHPD provides versatile comfort across a range of climates by providing reliable comfort with a variable output that eliminates short cycling for lasting efficiency. Use our sizing calculator (found\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/hvacdirect.com\/sizing-air-conditioner-and-heater.html\" target=\"_blank\"\u003eHERE\u003c\/a\u003e) to determine the demand for your home.\u003c\/p\u003e\n\u003ctable class=\"data table additional-attributes\" id=\"product-attribute-specs-table\"\u003e\n\u003ctbody data-role=\"additional-info\" class=\"child-product-section\" data-additional-product-id=\"194646\"\u003e\n\u003ctr\u003e\n\u003cth colspan=\"2\" scope=\"row\"\u003eACIQ 4 Ton 16 SEER2 High Efficiency Heat Pump Condenser - R454B Inverter\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"tr-title\"\u003e\n\u003cth class=\"border-left\"\u003eFeature\u003c\/th\u003e\n\u003cth class=\"border-right\"\u003eSpec\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eSKU\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"SKU\"\u003eACIQ-48-EHPD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eRefrigerant Charge\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Refrigerant Charge\"\u003e134.04 oz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Weight\"\u003e224.210000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eManufacturer\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Manufacturer\"\u003eACiQ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eReplaces\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Replaces\"\u003eACIQ-48-EHPB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eProduct Features\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Product Features\"\u003eHigh Efficiency \/ Inverter, Two Stage Condenser, Variable Speed Condenser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eHSPF2\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"HSPF2\"\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eCooling BTU\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Cooling BTU\"\u003e48,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eHeating BTU\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Heating BTU\"\u003e48,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eMaximum CFM\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Maximum CFM\"\u003e3037.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eDecibel Level (dBA)\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Decibel Level (dBA)\"\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eElectric Heat\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Electric Heat\"\u003eHeat Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eRefrigerant\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Refrigerant\"\u003eR454B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eSEER2\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"SEER2\"\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eCondenser Stages\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Condenser Stages\"\u003eVariable Speed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eCompressor Type\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Compressor Type\"\u003eRotary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eLiquid Valve Size\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Liquid Valve Size\"\u003e3\/8\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eSuction Valve Size\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Suction Valve Size\"\u003e3\/4\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eElectrical\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Electrical\"\u003e208\/230V, 1 Phase, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eElectric Phase Filter\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Electric Phase Filter\"\u003eSingle Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eMax Breaker Size\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Max Breaker Size\"\u003e40 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eMin. Breaker Size\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Min. Breaker Size\"\u003e36 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eTonnage\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Tonnage\"\u003e4 Ton\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eMin\/Max Outdoor Temp for Heating\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Min\/Max Outdoor Temp for Heating\"\u003e-13°F - 75°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eMin\/Max Outdoor Temp for Cooling\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Min\/Max Outdoor Temp for Cooling\"\u003e-13°F - 122°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eZone Compatibility\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Zone Compatibility\"\u003eSingle Zone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eAmbient Temperature Range\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Ambient Temperature Range\"\u003e-13°F - 122°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eHeight\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Height\"\u003e38.39\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eWidth\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Width\"\u003e38.58\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eDepth\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Depth\"\u003e16.34\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Warranty\"\u003e12 Years Compressor and 7 Years Parts with Online Registration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eResources\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Resources\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.aciq.com\/media\/pdf\/ACiQ-Quick-Start-Guide-AHD-HPD-454B.pdf\"\u003eQuick Start Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.aciq.com\/media\/pdf\/ACiQ-AHRI-48-AHD-48-EHPD-031725.pdf\"\u003e4 Ton EHPD \/ AHD AHRI Certificate\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.aciq.com\/media\/pdf\/ACIQ-AHD-NCL-Sub-48K-AHD-48K-EHPD-122424.pdf\"\u003e4 Ton EHPD \/ AHD Submittal\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.aciq.com\/media\/pdf\/ACiQ-HPD-EHPD-im-en-01-022625(16123000A33051).pdf\"\u003eCondenser Installation Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.aciq.com\/media\/pdf\/ACiQ-HPD-EHPD-sm-en-01-061825(NB_H_241119_41-12K-60K-EHPD-HPD).pdf\"\u003eCondenser Service Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.aciq.com\/media\/pdf\/ACiQ-48K-AHD-48K-EHPD-EPT-en-01-041025.pdf\"\u003e4 Ton EHPD \/ AHD Extended Performance Tables\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.aciq.com\/media\/pdf\/ACiQ-AHD-EHPD-HPD-Nominal-Capacity-Performance-Chart-040825.pdf\"\u003eEHPD \/ HPD \/ AHD \/ PAH Nominal Capacity Performance Chart\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.aciq.com\/media\/pdf\/ACIQ_24v_Warning_2025_v1.pdf\"\u003eACiQ 24 Volt Wiring Notice\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"https:\/\/portal.aciq.com\/media\/pdf\/aciq-mini-split-HES-warranty-12YR-Edit-2-8-4-2-1.pdf\"\u003eWarranty\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\nYou will need Adobe® Acrobat® Reader to view PDF documents.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth class=\"col label\" scope=\"row\"\u003eSafety Information\u003c\/th\u003e\n\u003ctd class=\"col data\" data-th=\"Safety Information\"\u003e\u003ca\u003ePROPOSITION 65 WARNING\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"ACiQ","offers":[{"title":"Default Title","offer_id":45430180544569,"sku":"ACIQ-48-EHPD","price":4450.75,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0754\/2938\/0153\/files\/aciq-48-ehpd_1_d6e885c9-44e2-4980-a785-0523005964ad.jpg?v=1770087554","url":"https:\/\/summitforgesupply.com\/products\/aciq-4-ton-16-seer2-high-efficiency-heat-pump-condenser-r454b-inverter-aciq-48-ehpd","provider":"Summit Forge Supply","version":"1.0","type":"link"}